Comparing two modeles

It will be great to have a comparaison tools between two or more modeles as I faced many times what version of the modele is the most updated specially when we loose track of the model or also when two firm works in the same model then at the end ...
10 months ago in Design 0

MCC used as Multi-Motor Unit (HVAC)

No description provided
3 months ago in Design 0

ArcPro Method Above 15kV

Have seen multiple owner review comments come back lately requesting that we use ArcPro method above 15kV. Seems OSHA may have some sort of new requirement to use ArcPro method above 15kV. Was trying to find out if EZP already has calcs similar to...
about 1 year ago in Arc Flash 1

Add support for calculation according to IEC61363-1

It is useful since it is required to use for documenting marine and offshore installations.
4 months ago in Short Circuit 0

Arc-Flash Label

The label design menu lacks several variables to make it truly useful for connection with the Maintenance Management Programs that offer data for devices.la When a QR code is integrated with the Arc Flash Label, several information that are subjec...
11 months ago in Arc Flash 0

Button for open file location and set default location

Add a button to File-Properties and Options-File Location to open the current project folder. Add a checkbox to set ALL project related files (not templates)to the current project folder. Unchecking this checkbox should revert back to the "documen...
4 months ago in Design 0

Open/Closed Transition ATS

Currently, ATS's can only operate in open transition mode. I would like the ability to run them in closed transition mode, where both sources feed the ATS at the same time. This would be useful so I do not have to manually modify scenarios to crea...
5 months ago in Short Circuit 0

Database Browser: Show grid in alternate rows highlighting

In the Database Report we show the alternate rows highlighted. This makes it easy to ready horizontally across the page. The Browser (grid) does not have that formatting. It will be easier in the browser too if we added highlighting in alternate r...
over 1 year ago in Others 0

Add voltage input to support 51V protection

voltage-restrained time overcurrent is common in generator protection and stright 50/51 is often not used. This leads to overly conservative trip times for generator breakers. It would be great if EasyPower could use the reduced voltage settings f...
5 months ago in Arc Flash 0

User Specified Electrode Gap in Open Air Arc Flash

As of right now, when a user specifies a bus as "open air" in order to use the arc flash options for "open air" calculations, the open air calculations force the electrode gap to the values from NFPA 70E Annex D.8 based on voltage, which are often...
6 months ago in Arc Flash 0