Display which breaker a relay trips in One-Line

Allow for the ability to put which breaker a relay trips into the relay's one-line text for situations where it is not entirely evident which breaker the relay would trip. Removing the need to put in notes manually.
8 months ago in One-line View & Edit 0

Inverter: Model time-varying contribution for faults and arc flash

Based on inverter data, allow specifying the fault current contribution over different cycles after initiation of faults.
11 months ago in Short Circuit 0

Open multiple Analysis reports in same Excel file in different tabs

I would like different analysis reports to be exported to a single Excel file but in different tabs. For example, short circuit can have different reports for Momentary, Interrupting, 30-cycle, HV, LV, Equipment Duty.
11 months ago in Import/Export 0

Relays: Model SEL Rating Method for overload curves

Model the Rating Thermal Method of SEL-749M. When selected, the relay configures a thermal curve based on the motor Full Load Amps, Service Factor, Run State Time Constant, Locked Rotor Amps, Hot Locked Rotor Time, and Acceleration Factor (Locked ...
11 months ago in Protection & Coordination 0

Arc Flash: Allow showing both Including and Excluding Main results in same Label

I would like to create labels such that the same label has arc flash results for both line side and load of the main breaker.
11 months ago in Arc Flash 0

Database Browser: Show grid in alternate rows highlighting

In the Database Report we show the alternate rows highlighted. This makes it easy to ready horizontally across the page. The Browser (grid) does not have that formatting. It will be easier in the browser too if we added highlighting in alternate r...
11 months ago in Others 0

DC Arc Flash: Modified Max Power method based on Curtis Ashton paper

We are facing challenges with DC arc flash assessments. The main issue is that the NFPA 70E Annex D.5 Max Power equation for DC incident energy calculations, which we have found to yield overly conservative results, particularly for battery banks....
11 months ago in Arc Flash 0

Change ID Name: Support replacing substring with a null/blank

I would like to remove EasyPower appended ID Name suffix text by replacing a given substring with a blank. The dialog does not accept a blank in the field "With these characters".
11 months ago in One-line View & Edit 0

One-line Printout: Show scenario name, data-block or analysis type

When printing one-lines, there is not currently a way to indicate automatically what the current view, or data-block, or calculation is set to. For example, if I have a One-line showing Arc Flash calculations for a specific scenario, or base case,...
11 months ago in One-line View & Edit 0

Equipment Duty Report: Include devices that have zero rating

I would like the equipment duty report to include devices that have zero short-circuit rating if the SC rating data fetched from the device library is zero.
11 months ago in Short Circuit 0