Add voltage input to support 51V protection

voltage-restrained time overcurrent is common in generator protection and stright 50/51 is often not used. This leads to overly conservative trip times for generator breakers. It would be great if EasyPower could use the reduced voltage settings f...
2 days ago in Arc Flash 0

Annotation Improvements

Greatly improve the annotations portion of Easypower (Note, Note w/Leader, Box, Line): Ability to set 'default' behaviour for all annotations (eg: fonts, line weights, arrow type, etc..). The way it should work: When any annotation tool is sel...
about 1 month ago in One-line View & Edit 1

User Specified Electrode Gap in Open Air Arc Flash

As of right now, when a user specifies a bus as "open air" in order to use the arc flash options for "open air" calculations, the open air calculations force the electrode gap to the values from NFPA 70E Annex D.8 based on voltage, which are often...
24 days ago in Arc Flash 0

Add cable symbology to one-line

Of all the physical device to not include on the one-line (and most of them are included) having the ability to show and edit the cable (or bus duct or perhaps overhead line) symbol would make it easier to recognize one the one-line
about 1 month ago in One-line View & Edit 0

Update TCC one-line to match model one-line

We recently added protection to the model but did not immediately verify the changes in the time-current curve. When we did look at the TCC sometime later, it looked like the original one-line with no indication of any changes. We missed the added...
about 1 month ago in Others 0

add "find style" option to the breaker trip sensor field (similar to the breaker type option)

make it easier to find the type of breaker trip sensor when the manufacturer is not known or when other info is not known
3 months ago in Data Collection 0

add items to the neutral listing of a conductor

A common practice in the utility world is to place three EPR 15kV insulated cables with tape shield and one bare neutral return. Please add the option of a bare copper cable in the neutral tab.
about 1 month ago in Design 0

Text Reports - Turn titles & headers off

Under Text Report, Format: add option to turn titles and headers off. Even better: add template for custom headers.
2 months ago in Others 0

Comparing two modeles

It will be great to have a comparaison tools between two or more modeles as I faced many times what version of the modele is the most updated specially when we loose track of the model or also when two firm works in the same model then at the end ...
5 months ago in Design 0

Put Equipment Duty Violation in Arc Flash Table

It would be nice to show violations of Equipment Duty ratings in the arc flash table in a separate column. Being able to automatically apply that information to a label is something many clients ask for.
10 months ago in Short Circuit 0