Add tab in equipment dialog box for NFPA-70B Documentation

Since there is more focus on NFPA-70B since the 2023 edition, we are getting more requests to collect a little more info on the equipment and provide that documentation along with our final study report. I recommend adding an additional NFPA-70B t...
17 days ago in Others

Add variable to arc flash label for worst case short circuit current.

On our arc flash labels, we currently have a line for the available fault current (Momentary Bus Current in Kilo Amps) that is associated with the worst case arc flash scenario. This does not always reflect the maximum available fault current. If ...
17 days ago in Short Circuit

Feature to include the UNDO function inside the Protection and Coordination tab

Under the Protection and Coordination tab, for both the single line and tcc window, after accidentally moving or deleting an item, theres no feature to undo the action causing waste of time.
15 days ago in Protection & Coordination

Show the worst-case incident energy in One-Line-Diagram

It would be great to showcase the worst-case incident energy to the buses in the one-line diagram. This way the client dont need to go back and forth on the tabulated Arc Flash Results and figure out the location of the buses with high incident en...
15 days ago in Arc Flash

Enable import of AutoCAD electrical drawings (i.e. One-line diagrams & supporting data) into EasyPower

Importing AutoCAD electrical one-line diagrams & relevant data would eliminate the need to have to re-create all that information in EasyPower.
16 days ago in Import/Export

MCC used as Multi-Motor Unit (HVAC)

No description provided
24 days ago in Design

MCC Elevation View Customization

There should be some added customization to the MCC Elevation View, such as option to add a front and back view to an MCC, each stack has a custom wire rack customizability for the side, top, bottom of the stack, and customizable order for some of...
about 2 months ago in Design

Increase Character Limit in MCC Equipment Name Column

This would help with the naming conventions that are being used by one of the customers we work with in EasyPower. The previous version, which was where the model was built, has an extended character limit in the Equipment Name Column so many of t...
about 2 months ago in Data Collection

Add support for calculation according to IEC61363-1

It is useful since it is required to use for documenting marine and offshore installations.
about 1 month ago in Short Circuit

Annotation Improvements

Greatly improve the annotations portion of Easypower (Note, Note w/Leader, Box, Line): Ability to set 'default' behaviour for all annotations (eg: fonts, line weights, arrow type, etc..). The way it should work: When any annotation tool is sel...
4 months ago in One-line View & Edit